Noninvasive measurement of intracranial pressure: Is it possible?
2007
BACKGROUND: Some publications suggest a strong correlation between the intracranial pressure and the intraocular pressure. Other studies claim no correlation between these two physiologic variables. Our aim was to study whether the tonometry could be a useful method to evaluate intracranial pressure in patients with suspected intracranial abnormality. METHODS: We evaluated the correlation between the intracranial pressure and the intraocular pressure, the intracranial pressure and the mean arterial pressure, and the intraocular pressure and the mean arterial pressure in 22 patients, initially comatose, who were admitted to our hospital. All patients required the intracranial pressure monito…
European Society of Hypertension practice guidelines for ambulatory blood pressure monitoring
2014
Given the increasing use of ambulatory blood pressure monitoring (ABPM) in both clinical practice and hypertension research, a group of scientists, participating in the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variability, in year 2013 published a comprehensive position paper dealing with all aspects of the technique, based on the available scientific evidence for ABPM. The present work represents an updated schematic summary of the most important aspects related to the use of ABPM in daily practice, and is aimed at providing recommendations for proper use of this technique in a clinical setting by both specialists and practicing physici…
Dependence of O2 diffusion dynamics on pressure and temperature in silica nanoparticles
2013
An experimental study of the molecular O2 diffusion process in high purity non-porous silica nanoparticles having 50 m2/g BET specific surface and 20 nm average radius was carried out in the temperature range from 127 to 177 °C at O2 pressure in the range from 0.2 to 66 bar. The study was performed by measuring the volume average interstitial O2 concentration by a Raman and photoluminescence technique using a 1,064 nm excitation laser to detect the singlet to triplet emission at 1,272 nm of the molecular oxygen in silica. A dependence of the diffusion kinetics on the O2 absolute pressure, in addition to temperature dependence, was found. The kinetics can be fit by the solution of Fick’s dif…
European society of hypertension position paper on ambulatory blood pressure monitoring
2013
Ambulatory blood pressure monitoring (ABPM) is being used increasingly in both clinical practice and hypertension research. Although there are many guidelines that emphasize the indications for ABPM, there is no comprehensive guideline dealing with all aspects of the technique. It was agreed at a consensus meeting on ABPM in Milan in 2011 that the 34 attendees should prepare a comprehensive position paper on the scientific evidence for ABPM.This position paper considers the historical background, the advantages and limitations of ABPM, the threshold levels for practice, and the cost-effectiveness of the technique. It examines the need for selecting an appropriate device, the accuracy of dev…
DETERMINATION OF TDC IN INTERNAL COMBUSTION ENGINES BY A NEWLY DEVELOPED THERMODYNAMIC APPROACH
2010
Abstract In-cylinder pressure analysis is nowadays an indispensable tool in internal combustion engine research & development. It allows the measure of some important performance related parameters, such as indicated mean effective pressure (IMEP), mean friction pressure, indicated fuel consumption, heat release rate, mass fraction burned, etc. Moreover, future automotive engine will probably be equipped with in-cylinder pressure sensors for continuous combustion monitoring and control, in order to fulfil the more and more strict emission limits. For these reasons, in-cylinder pressure analysis must be carried out with maximum accuracy, in order to minimize the effects of its characteristic…
Self-blood pressure monitoring as a tool to increase hypertension awareness, adherence to antihypertensive therapy, and blood pressure control
2019
For many years, casual blood pressure (BP) taken by a sphygmomanometer in the clinic or at the physician's office has been used as the standard method for diagnosing hypertension. Even if such measurement has been the cornerstone on which our understanding of the consequences of hypertension is based, there is a huge and very consistent body of evidence indicating that casual measurements of BP may provide a very unreliable index for the evaluation of hypertension because of their variability. The two alternative ways of measuring BP that have been most commonly used are measurements made at home by the patient himself (home or self‐BP monitoring—SBPM) and measurements by ambulatory blood p…
Pressure measurements of TO-phonon anharmonicity in isotopic ZnS
2004
We have measured the dependence on pressure of the line-widths of the TO and LO Raman phonons of β-ZnS. In order to enhance the phenomena observed, and to eliminate possible effects of isotopic disorder, we have measured a nearly isotopically pure crystal, 68 Zn 32 S. The strongly structured pressure effects observed are interpreted on the basis of anharmonic decay and the corresponding two-phonon density of states.
A Laboratory Scale Equipment to Relieve Force and Pressure in Cold Extrusion of Lead Hollow Components
2008
Nowadays, many researchers are involved in studies aimed to the explanation of some peculiar aspects regarding manufacturing processes. In this paper, an experimental campaign was carried out in order to reproduce tube extrusion starting from a cylindrical billet. In particular, the development of a proper equipment is presented: the aim was to measure both the total load, by using the testing machine load cell, and the local pressure value on the porthole. The latter task was carried out performing a proper system based on the use of a small load-cell. The tube was extruded with a good surface quality and the external area does not show any welding line evidence. Pure Lead was used for the…
A phenomenological model for the quantitative interpretation of partial suspension conditions in stirred vessels
2000
Publisher Summary Many important chemical engineering operations involve the suspension of solid particles in a liquid phase inside stirred tanks. Relevant examples include adsorption, crystallization, dissolution, leaching, precipitation, ion exchange and catalytic multiphase processes. This chapter describes a phenomenological model for the quantitative determination of the suspended solids mass fraction in stirred tanks operated at partial suspension conditions. Experimental data on fractional suspension, obtained by the “Pressure Gauge Technique” in vessels stirred by a downward-pumping pitched-blade-turbine, are presented. Furthermore, model predicted trends are compared with experimen…
Measuring the Rate of Information Transfer in Point-Process Data: Application to Cardiovascular Interactions
2021
We present the implementation to cardiovascular variability of a method for the information-theoretic estimation of the directed interactions between event-based data. The method allows to compute the transfer entropy rate (TER) from a source to a target point process in continuous time, thus overcoming the severe limitations associated with time discretization of event-based processes. In this work, the method is evaluated on coupled cardiovascular point processes representing the heartbeat dynamics and the related peripheral pulsation, first using a physiologically-based simulation model and then studying real point-process data from healthy subjects monitored at rest and during postural …